If a hood is to be installed above the hob, refer to the hood installation instructions to ensure the correct
height above the hob
Note: If the distance “A” between the wall cupboards in the kitchen is between 600mm and 730mm, the
height “B” must be at least 530mm.
If the distance “A” between the wall cupboards is greater than the width of the hob, the height “B” must
be at least 400 mm.
Hood and cabinetry clearances (mm)
Category II2E+3+
Electric power: 230 V ~ 50 Hz
Injectors table
6
in. R
70 min.
Type of gas used Type of
burner
Injector
label
Control
primary air
(X) mm
Nominal heat
flow kW
Nominal
consumption
Reduced heat
flow
Gas pressure
(mbar)
BE FR min. nom. max.
NATURAL GAS
(Methane) G20
wok 145 6 4.20 400 l/h 1.55 1.55
17 20 25
rapid 128 – 3.00 286 l/h 0.80 0.60
semi-rapid 95 – 1.65 157 l/h 0.45 0.35
auxiliary 78 – 1.00 95 l/h 0.35 0.30
NATURAL GAS
(Methane) G25
wok 154 5.5 4.20 465 l/h 1.55 1.55
20 25 30
rapid 132 – 3.00 332 l/h 0.60 0.60
semi-rapid 100 – 1.65 183 l/h 0.35 0.35
auxiliary 79 – 1.00 111 l/h 0.30 0.30
LIQUID PETROLEUM GAS
(Butane) G30
wok 95 11 3.80 276 g/h 1.55 1.55
20 28-30 35
rapid 87 – 3.00 218 g/h 0.60 0.60
semi-rapid 67 – 1.65 120 g/h 0.35 0.35
auxiliary 50 – 1.00 73 g/h 0.30 0.30
LIQUID PETROLEUM GAS
(Propane) G31
wok 95 11 3.80 272 g/h 1.55 1.55
25 37 45
rapid 87 – 3.00 214 g/h 0.60 0.60
semi-rapid 67 – 1.65 118 g/h 0.35 0.35
auxiliary 50 – 1.00 71 g/h 0.30 0.30
Type of gas
used
Configuration
model
Nominal heat flow
kW
Overall nominal
consumption
Required air (m
3
) for the
combustion 1 m
3
of gas
G20 20 mbar 5 burners 11.50 1092 l/h 9.52
G25 25 mbar 5 burners 11.50 1274 l/h 8.187
G30 28-30 mbar 5 burners 11.10 807 g/h 30.94
G31 37 mbar 5 burners 11.10 793 g/h 23.80