If a hood is to be installed above the hob, refer to the hood installation instructions to ensure the correct
height above the hob
Note: If the distance “A” between the wall cupboards in the kitchen is between 600mm and 730mm, the
height “B” must be at least 530mm.
If the distance “A” between the wall cupboards is greater than the width of the hob, the height “B” must
be at least 400 mm.
Hood and cabinetry clearances (mm)
min. R 6,5
63 min.
Category II2L3B/P
Electric Power: 230 V ~ 50 Hz
Type of gas used Type of burner Injector label
Control primary
air (X) mm
Nominal heat
flow kW
Nominal
consumption
Reduced heat
flow kW
Gas pressure (mbar)
min. nom.
max
NATURAL GAS
(Methane) G25
wok
semi-rapid
auxiliary
154
102
79
5,5
-
-
4,20
1,65
1,00
465 l/h
183 l/h
111 l/h
1,55
0,35
0,35
20 25 30
LIQUID
PETROLEUM GAS
(Butane) G30
(Propane) G31
wok
semi-rapid
auxiliary
95
67
50
11
-
-
3,80
1,65
1,00
276 g/h
120 g/h
73 g/h
1,55
0,35
0,30
25 30 35
Type of gas used Configuration model Nominal heat flow kW Overall nominal consumption
Required air (m
3
) for
the combustion 1 m
3
of gas
G25 25 mbar
G30/G31 30 mbar
3C - 2 SR - 1 AUX
3C - 2 SR - 1 AUX
8,50
8,10
942 l/h
589 g/h
8,187
30,94